Barry Electronics Ltd. has opened a new online shop. This will mainly feature smaller equipment and is aimed at smaller fishing vessels, leisure, etc. You can access the online shop by clicking the ‘Shop’ link at the top of our main website page or by clicking here. Please contact us directly for any queries regarding larger equipment.
A GPS rollover will occur in December 2020 which will affect the following Furuno products:
Felcom 15.
Units affected: Serial number before 3533-9371.
Symptom: Actual communication is not affected but the date is not automatically updated and is incorrectly displayed in SSAS and VMS reports.
Remedy: Software update and replacement of internal GPS module – contact Barry Electronics.
Note: This only applies to units with built-in GPS. If GPS is being fed from a separate GPS receiver, no action need be taken.
Felcom 16.
Units affected: Serial number before 3534-2756.
Symptom: Actual communication is not affected but the date is not automatically updated and is incorrectly displayed in SSAS and VMS reports.
Remedy: For serial no. before 3534-2756, software update and replacement of internal GPS module. For serial no. after 3534-2756, software update – contact Barry Electronics.
Felcom 70.
Units affected: All.
Symptom: Regardless of rollover, Inmarsat will cease their Fleet 77 service in December 2020.
Remedy: Replace equipment.
FA-100 AIS.
Units affected: All.
Symptom: AIS communication will continue to operate but internal logs (messages, etc.) will have incorrect date.
Remedy: Replace equipment.
GP-310B GPS receiver antenna.
Units affected: Serial number before 3453-5687.
Symptom: Unit will cease to function.
Remedy: Replace unit.
GP-80 GPS
Units affected: Serial numbers in the range 2477-8733 to 3457-3275.
Symptom: Date will roll back to 1st August, 1999.
Remedy: It is recommended to replace unit.
GP-90 GPS
Units affected: All units.
Symptom: Expected to fail by June, 2021 or, in some cases, by January, 2022.
Remedy: It is recommended to replace unit.
GP-150 GPS
Units affected: All units.
Symptoms: Expected to fail at rollover in January, 2022.
Remedy: Software update – please contact Barry Electronics.
If in doubt, please contact us for advice.